Thank you for taking an interest in our selection of 6685-01-484-1772 parts here on Boost AOG. You are currently on the RFQ form for part number 651CD2S1N, a Ogden Air Logistics Center product listed with the Indicator Pressure If part number 651CD2S1N catches your eye, be sure to use our online RFQ service to request quotes, with customized responses provided within 15 minutes of us receiving and reviewing a completed submission.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure the quality of our NSN components, we adhere to a strict NO CHINA SOURCING pledge, meaning every purchased item will be delivered alongside any pertinent qualifying certifications or manufacturing trace documentation for your benefit. Paired with numerous other commitments, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. If you happen to be facing a time constraint and require NSN parts quickly, contact us at your earliest convenience, and we will discuss the expedited shipping options we have available for domestic and international customers alike. With our various dedications in mind, kick off procurement for Ogden Air Logistics Center part number 651CD2S1N and other Indicator Pressure products today.
MRC | Criteria | Characteristic |
---|---|---|
FAAZ | Phase | SINGLE |
ACYN | Ac Voltage Rating | 90.0 VOLTS MINIMUM AND 264.0 VOLTS MAXIMUM |
ACDC | Current Type | AC |
BFQN | Display Type | LIQUID CRYSTAL |
ACZB | Frequency Rating | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
HGTH | Height | 3.500 INCHES NOMINAL |
AEJZ | Depth | 9.000 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 4 PANEL |
CXCY | Part Name Assigned By Controlling Agency | CONTROLLER,PID PRESSURE,DIGITAL TYPE 651C |
ABGL | Width | 9.500 INCHES NOMINAL |
FEAT | Special Features | HINCLUDES ADJUSTABLE SOFT-START FUNCTIONS FOR EACH SET POINT,AS WELL AS OPEN AND CLOSE FUNCTINS TO MINIMIZE TURBULENCE IN THE CHAMBER;LOCAL/REMOTE TRANSDUCER ZEROING CAPABILITY;TWO RELAYS TO ACTIVATE OTHER SYSTEM FUNCTIONS, ORTO INDICATE IF PRESSURE DEVIATES FROM THE DESIRED SET POINT; AN LCD READOUT SHOWS VALVE POSITION AND DISPLAYS PRESSURE IN A WIDE RANGE OF ENGINEERING UNITS; FIVE REPROGRAMMABLE SET POINTS ARE PROVIDED FOR PRESSURE OR POSITION CONTROL |
AGAV | End Item Identification | REENTRY SYSTEM TEST SET(RSTS) |
MRC | Decoded Requirement | Clear Text Reply |
AMNL | Presentation Type | DIGITAL DISPLAY |
ASKX | Electrical Connection Quantity | 1 |