Thank you for taking an interest in our selection of 5985-01-276-2425 parts here on Boost AOG. You are currently on the RFQ form for part number R12-960, a Microwave Engineering Corporation product listed with the Waveguideassembly If part number R12-960 catches your eye, be sure to use our online RFQ service to request quotes, with customized responses provided within 15 minutes of us receiving and reviewing a completed submission.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure the quality of our NSN components, we adhere to a strict NO CHINA SOURCING pledge, meaning every purchased item will be delivered alongside any pertinent qualifying certifications or manufacturing trace documentation for your benefit. Paired with numerous other commitments, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. If you happen to be facing a time constraint and require NSN parts quickly, contact us at your earliest convenience, and we will discuss the expedited shipping options we have available for domestic and international customers alike. With our various dedications in mind, kick off procurement for Microwave Engineering Corporation part number R12-960 and other Waveguideassembly products today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-276-2425 Item PartTypeName: WAVEGUIDE ASSEMBLY | 5985 | 012762425 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
SPM34546 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 1.253 INCHES MINIMUM FIRST FLANGE AND 1.256 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.628 INCHES MINIMUM FIRST FLANGE AND 0.631 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM FIRST FLANGE AND 0.453 INCHES MAXIMUM FIRST FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.05 |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |
CRFH | WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
CSPL | WAVEGUIDE LONGER OFFSET DISTANCE | 3.500 INCHES NOMINAL |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | COVER TYPE FIRST FLANGE |
CWBG | WAVEGUIDE OFFSET DISTANCE | 3.000 INCHES NOMINAL |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY FIRST FLANGE |
MATT | MATERIAL | COPPER ALLOY SINGLE TUBING SEGMENT |
SFTT | SURFACE TREATMENT | PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
STYL | STYLE DESIGNATOR | BEND TYPE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.