Thank you for taking an interest in our selection of 6625-00-556-8936 parts here on Boost AOG. You are currently on the RFQ form for part number 233A, a Joint Electronics Type Designation System product listed with the Generator Signal If part number 233A catches your eye, be sure to use our online RFQ service to request quotes, with customized responses provided within 15 minutes of us receiving and reviewing a completed submission.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure the quality of our NSN components, we adhere to a strict NO CHINA SOURCING pledge, meaning every purchased item will be delivered alongside any pertinent qualifying certifications or manufacturing trace documentation for your benefit. Paired with numerous other commitments, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. If you happen to be facing a time constraint and require NSN parts quickly, contact us at your earliest convenience, and we will discuss the expedited shipping options we have available for domestic and international customers alike. With our various dedications in mind, kick off procurement for Joint Electronics Type Designation System part number 233A and other Generator Signal products today.
MRC | Criteria | Characteristic |
---|---|---|
AFGQ | FREQUENCY RANGE RATING | 0.050 TO 500.000 HERTZ |
SR-5 | THE MANUFACTURERS DATA | |
AAXX | MOUNTING TYPE | RACK |
ADTY | CASE SURFACE TREATMENT | ENAMELED |
FAAZ | PHASE | SINGLE |
BHGB | MAXIMUM SIGNAL OUTPUT | 6 V |
BHGD | MODULATOR LOCATION | EXTERNAL |
SR-5 | MANUFACTURERS CODE | 1LQK8 |
BHFY | CRYSTAL CONTROLLED FEATURE | NOT PROVIDED |
SR-5 | DESIGN CONTROL REFERENCE | 233A |
ABHP | OVERALL LENGTH | 17.125 INCHES NOMINAL |
AMSE | VOLTAGE RATING | 115.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM |
ADTV | CASE MATERIAL | ALUMINUM |
BDHW | CALIBRATION ACCURACY RATING | 2 PCT |
AYYE | MODULATION TYPE | AM |
RDAL | III REFERENCE DATA AND LITERATURE | 33A1-147-1 |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 100.0 HERTZ MAXIMUM |
BHQD | MODULATED FREQUENCY RATING | 150.0 HERTZ NOMINAL |
BHQG | MODULATION DEGREE | 60.0 PERCENT NOMINAL |
FTLD | III FUNCTIONAL DESCRIPTION | TEST TONE SOURCE FOR USE WITH OPEN WIRE CARRIER TELEPHONE SYSTEMS EMPLOYING TERMINAL TELEPHONES |
ABMK | OVERALL WIDTH | 15.000 INCHES NOMINAL |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
ABKW | OVERALL HEIGHT | 10.250 INCHES NOMINAL |
BHGC | SIGNAL OUTPUT CONSTANCY | 2 DB MAX VARIATION THROUGHOUT FREQUENCY RANGE |
AMNE | OUTPUT IMPEDANCE RATING | 600.0 OHMS NOMINAL |
ACDC | CURRENT TYPE | AC |
ANLC | FREQUENCY BAND QUANTITY | 4 |