Thank you for taking an interest in our selection of 5915-00-922-9148 parts here on Boost AOG. You are currently on the RFQ form for part number FSR-W-100B4, a Filtron Co Inc product listed with the Filter Radio Frequency Interfere If part number FSR-W-100B4 catches your eye, be sure to use our online RFQ service to request quotes, with customized responses provided within 15 minutes of us receiving and reviewing a completed submission.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure the quality of our NSN components, we adhere to a strict NO CHINA SOURCING pledge, meaning every purchased item will be delivered alongside any pertinent qualifying certifications or manufacturing trace documentation for your benefit. Paired with numerous other commitments, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. If you happen to be facing a time constraint and require NSN parts quickly, contact us at your earliest convenience, and we will discuss the expedited shipping options we have available for domestic and international customers alike. With our various dedications in mind, kick off procurement for Filtron Co Inc part number FSR-W-100B4 and other Filter Radio Frequency Interfere products today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-922-9148 Item PartTypeName: FILTER,RADIO FREQUENCY INTERFERE | 5915 | 009229148 | 0 | Y | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
4N100 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 100.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 100.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 100.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 100.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 25.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 25.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 25.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 25.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | CORROSION RESISTANT |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB,SOLDER LUG INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB,SOLDER LUG OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 277.0 VOLTS AC 1ST RADIO INTERFERENCE AND 600.0 VOLTS DC 2ND RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 277.0 VOLTS AC 2ND RADIO INTERFERENCE AND 600.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 277.0 VOLTS AC 3RD RADIO INTERFERENCE AND 600.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 277.0 VOLTS AC 4TH RADIO INTERFERENCE AND 600.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQRG | BODY MATERIAL | METAL |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 1.2 KILOVOLTS AT SEA LEVEL |
CTJS | UNPACKAGED UNIT WEIGHT | 290.000 POUNDS NOMINAL |
FEAT | SPECIAL FEATURES | FOUR FILTERED FUNCTIONS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
ABKW | OVERALL HEIGHT | 39.000 INCHES NOMINAL |
ADAQ | BODY LENGTH | 25.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 11.000 INCHES NOMINAL |
ADAU | BODY HEIGHT | 27.000 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 2.000 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 27.000 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 25.000 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.