Thank you for taking an interest in our selection of 5925-01-406-2867 parts here on Boost AOG. You are currently on the RFQ form for part number CE3-G3-AB0030-01B, a Eaton Corporation product listed with the Circuit Breaker If part number CE3-G3-AB0030-01B catches your eye, be sure to use our online RFQ service to request quotes, with customized responses provided within 15 minutes of us receiving and reviewing a completed submission.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure the quality of our NSN components, we adhere to a strict NO CHINA SOURCING pledge, meaning every purchased item will be delivered alongside any pertinent qualifying certifications or manufacturing trace documentation for your benefit. Paired with numerous other commitments, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. If you happen to be facing a time constraint and require NSN parts quickly, contact us at your earliest convenience, and we will discuss the expedited shipping options we have available for domestic and international customers alike. With our various dedications in mind, kick off procurement for Eaton Corporation part number CE3-G3-AB0030-01B and other Circuit Breaker products today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-406-2867 Item Description: Circuit Breaker | 5925 | 014062867 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ce3-G3-Ab0030-01b | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 105.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.750 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC ALL LOCATIONS |
AJEC | Boss Height | 0.219 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.026 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
ADAT | Body Width | 3.138 INCHES NOMINAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.609 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 5.800 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 4.750 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
TTQY | Terminal Type And Quantity | 6 COMPRESSION |
MRC | Decoded Requirement | Clear Text Reply |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.026 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 460.0 AC ALL LOCATIONS |
THSD | Thread Series Designator | UNC |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 50.000 MINIMUM AT 200 PCT AND |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |