Thank you for taking an interest in our selection of 5925-01-131-2137 parts here on Boost AOG. You are currently on the RFQ form for part number AM3-2353-13, a Eaton Corporation product listed with the Circuit Breaker If part number AM3-2353-13 catches your eye, be sure to use our online RFQ service to request quotes, with customized responses provided within 15 minutes of us receiving and reviewing a completed submission.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure the quality of our NSN components, we adhere to a strict NO CHINA SOURCING pledge, meaning every purchased item will be delivered alongside any pertinent qualifying certifications or manufacturing trace documentation for your benefit. Paired with numerous other commitments, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. If you happen to be facing a time constraint and require NSN parts quickly, contact us at your earliest convenience, and we will discuss the expedited shipping options we have available for domestic and international customers alike. With our various dedications in mind, kick off procurement for Eaton Corporation part number AM3-2353-13 and other Circuit Breaker products today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-131-2137 Item Description: Circuit Breaker | 5925 | 011312137 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Am3-2353-13 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
AKPX | Pole Quantity | 3 |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CQXF | Inclosure Protection Type For Which Designed | HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT AND SALT SPRAY PROOF |
CPLM | Maximum Continuous Load Current Rating Per Pole | 25.0 AMPERES AC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
AJWX | Mounting Surface To Terminal End Distance | 2.625 INCHES MAXIMUM |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 AC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE THREE |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
AJEC | Boss Height | 0.150 INCHES NOMINAL |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CSSX | Switch Current Rating And Type In Amps | 10.0 AC AND 10.0 DC |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 115.0 ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
THSD | Thread Series Designator | UNC |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
ADAT | Body Width | 2.265 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT EACH POLE |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND 65.0 DC |
AAJE | Thread Pitch Diameters | +0.1177/+0.1214 INCHES |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADAQ | Body Length | 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
BBRJ | Special Handling Feature | MAGNETIC |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
PKWT | Unpackaged Unit Weight | 11.100 OUNCES |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CMLP | Thread Quantity Per Inch | 32 |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AEBV | Unthreaded Mounting Hole Diameter | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |