Thank you for taking an interest in our selection of 5925-01-075-9491 parts here on Boost AOG. You are currently on the RFQ form for part number AM333HEMG6-6-250VAC-4-50, a Eaton Corporation product listed with the Circuit Breaker If part number AM333HEMG6-6-250VAC-4-50 catches your eye, be sure to use our online RFQ service to request quotes, with customized responses provided within 15 minutes of us receiving and reviewing a completed submission.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure the quality of our NSN components, we adhere to a strict NO CHINA SOURCING pledge, meaning every purchased item will be delivered alongside any pertinent qualifying certifications or manufacturing trace documentation for your benefit. Paired with numerous other commitments, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. If you happen to be facing a time constraint and require NSN parts quickly, contact us at your earliest convenience, and we will discuss the expedited shipping options we have available for domestic and international customers alike. With our various dedications in mind, kick off procurement for Eaton Corporation part number AM333HEMG6-6-250VAC-4-50 and other Circuit Breaker products today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-075-9491 Item Description: CIRCUIT BREAKER | 5925 | 010759491 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM333HEMG6-6-250VAC-4-50 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 3 |
CSSX | Switch Current Rating And Type In Amps | 2.5 AC |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
CPLM | Maximum Continuous Load Current Rating Per Pole | 6.0 AMPERES AC ALL LOCATIONS |
PKWT | Unpackaged Unit Weight | 12.750 OUNCES |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
MRC | Decoded Requirement | Clear Text Reply |
CQSM | Switch Location And Position Designation | EXTERNAL AT POLE ONE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CPRP | Ultimate Trip Time Per Pole In Seconds | 80.000 MAXIMUM ALL LOCATIONS |
AJEC | Boss Height | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
CPRQ | Reset Method | MANUAL |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRX | Actuator Position Designation | AT EACH POLE |
ADAT | Body Width | 2.240 INCHES MINIMUM AND 2.260 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
THSD | Thread Series Designator | UNC |
AJWX | Mounting Surface To Terminal End Distance | 2.409 INCHES MINIMUM AND 2.523 INCHES MAXIMUM |
ADAQ | Body Length | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 8.500 MINIMUM AT 150 PCT ALL LOCATIONS AND 30.000 MAXIMUM AT 150 PCT ALL LOCATIONS AND 4.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 13.000 MAXIMUM AT 200 PCT ALL LOCATIONS AND 0.600 MINIMUM AT 400 PCT ALL LOCATIONS AND 2.000 MAXIMUM AT 400 PCT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
CMLP | Thread Quantity Per Inch | 32 |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote