Thank you for taking an interest in our selection of 5925-00-881-9765 parts here on Boost AOG. You are currently on the RFQ form for part number 260-0953-010, a Eaton Corporation product listed with the Circuit Breaker If part number 260-0953-010 catches your eye, be sure to use our online RFQ service to request quotes, with customized responses provided within 15 minutes of us receiving and reviewing a completed submission.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure the quality of our NSN components, we adhere to a strict NO CHINA SOURCING pledge, meaning every purchased item will be delivered alongside any pertinent qualifying certifications or manufacturing trace documentation for your benefit. Paired with numerous other commitments, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. If you happen to be facing a time constraint and require NSN parts quickly, contact us at your earliest convenience, and we will discuss the expedited shipping options we have available for domestic and international customers alike. With our various dedications in mind, kick off procurement for Eaton Corporation part number 260-0953-010 and other Circuit Breaker products today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-881-9765 Item PartTypeName: CIRCUIT BREAKER | 5925 | 008819765 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
79-149-1 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ADAT | BODY WIDTH | 1.562 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 4.0 AMPERES DC FIRST LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 6.0 AMPERES AC THIRD LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC THIRD LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC SECOND LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP FIRST LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
TTQY | TERMINAL TYPE AND QUANTITY | 10 WIRE HOOK |
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ABXD | BUSHING LENGTH | 0.330 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.937 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.875 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
AKPX | POLE QUANTITY | 3 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 4.0 AMPERES DC SECOND LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC FIRST LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 0.500 NOMINAL ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP SECOND LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP THIRD LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.280 NOMINAL AT 150 PCT ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNEF |