Thank you for taking an interest in our selection of 5925-00-336-1992 parts here on Boost AOG. You are currently on the RFQ form for part number JC3-C3-15-2, a Eaton Corporation product listed with the Circuit Breaker If part number JC3-C3-15-2 catches your eye, be sure to use our online RFQ service to request quotes, with customized responses provided within 15 minutes of us receiving and reviewing a completed submission.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure the quality of our NSN components, we adhere to a strict NO CHINA SOURCING pledge, meaning every purchased item will be delivered alongside any pertinent qualifying certifications or manufacturing trace documentation for your benefit. Paired with numerous other commitments, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. If you happen to be facing a time constraint and require NSN parts quickly, contact us at your earliest convenience, and we will discuss the expedited shipping options we have available for domestic and international customers alike. With our various dedications in mind, kick off procurement for Eaton Corporation part number JC3-C3-15-2 and other Circuit Breaker products today.
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 3 |
ABXD | Bushing Length | 0.098 INCHES MINIMUM AND 0.162 INCHES MAXIMUM |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.718 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
TTQY | Terminal Type And Quantity | 6 QUICK DISCONNECT, MALE |
THSD | Thread Series Designator | UNC |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
ADAT | Body Width | 2.218 INCHES MINIMUM AND 2.282 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
CQJX | Nominal Thread Size | 0.138 INCHES |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
AJWX | Mounting Surface To Terminal End Distance | 1.898 INCHES MINIMUM AND 1.962 INCHES MAXIMUM |
ADAQ | Body Length | 1.968 INCHES MINIMUM AND 2.032 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.528 INCHES MINIMUM AND 1.592 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.718 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CMLP | Thread Quantity Per Inch | 32 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRQ | Reset Method | MANUAL |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
MRC | Decoded Requirement | Clear Text Reply |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.628 INCHES MINIMUM AND 1.692 INCHES MAXIMUM |