Thank you for taking an interest in our selection of 5925-00-988-7855 parts here on Boost AOG. You are currently on the RFQ form for part number 5703646-503, a C Systems Llc product listed with the Circuit Breaker If part number 5703646-503 catches your eye, be sure to use our online RFQ service to request quotes, with customized responses provided within 15 minutes of us receiving and reviewing a completed submission.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure the quality of our NSN components, we adhere to a strict NO CHINA SOURCING pledge, meaning every purchased item will be delivered alongside any pertinent qualifying certifications or manufacturing trace documentation for your benefit. Paired with numerous other commitments, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. If you happen to be facing a time constraint and require NSN parts quickly, contact us at your earliest convenience, and we will discuss the expedited shipping options we have available for domestic and international customers alike. With our various dedications in mind, kick off procurement for C Systems Llc part number 5703646-503 and other Circuit Breaker products today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-988-7855 Item Description: NO ITEM NAME AVAILABLE | 5925 | 009887855 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5703646&503 | 1 | C |
MRC | Criteria | Characteristic |
---|---|---|
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.950 INCHES MAXIMUM |
ADAT | Body Width | 2.290 INCHES MAXIMUM |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.058 INCHES MINIMUM AND |
BBRJ | Special Handling Feature | MAGNETIC |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC ALL LOCATIONS |
PKWT | Unpackaged Unit Weight | 0.280 POUNDS |
AKPX | Pole Quantity | 3 |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 INCHES MINIMUM AND |
AJWX | Mounting Surface To Terminal End Distance | 2.620 INCHES MINIMUM AND |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.760 INCHES MAXIMUM |
AJEC | Boss Height | 0.140 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 115.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AJEC | Boss Height | 0.120 INCHES MINIMUM AND |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
AAJE | Thread Pitch Diameters | 0.1177 TO 0.1214 INCHES |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.640 INCHES MAXIMUM |
THSD | Thread Series Designator | UNC |
ADAQ | Body Length | 2.565 INCHES MINIMUM AND |
ADAQ | Body Length | 2.595 INCHES MAXIMUM |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.930 INCHES MINIMUM AND |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.760 INCHES MAXIMUM |
ADAT | Body Width | 2.270 INCHES MINIMUM AND |
CMLP | Thread Quantity Per Inch | 32 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.200 MINIMUM AT 200 PCT AND |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
MRC | Decoded Requirement | Clear Text Reply |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.078 INCHES MAXIMUM |
CQXF | Inclosure Protection Type For Which Designed | MOISTURE RESISTANT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote