If you are looking for NSN 6130-01-325-6734 supplies, turn to Boost AOG and our vast collection of offerings. On this page, we have arranged our NSN 6130-01-325-6734 inventory, where part numbers like ECV12D1, G12-4410, and others are presented alongside relevant information about this NSN for your perusal. Take the time to browse our ever-expanding selection of components as you see fit, and if any particular items pique your interest, be sure to use our online RFQ service to request quotes for your consideration.
All manufacturers and suppliers whose parts we sell are carefully evaluated by our staff as necessary, and a myriad of products we carry are subjected to diverse levels of testing and inspection for fit, form, and function. Additionally, we are fully committed to addressing the time limitations of our customers who shop on Boost AOG, providing options for accelerated shipping based on availability. Keeping this in mind, do not hesitate to reach out to us directly by phone or email, and our knowledgeable team members would be more than happy to help you obtain the NSN 6130-01-325-6734 parts you desire.
Item Name | Power Supply |
Federal Supply Group (FSG) | Electric Wire and Power and Distribution Equipment |
Federal Supply Class (FSC) | 6130 Converters Electrical Non Rotating |
National Item Identification Number (NIIN) | 01-325-6734 (013256734) |
NCB Code | USA (01) |
Manufacturer | Astec America Inc, Liebert Corp |
MRC | Criteria | Characteristic |
---|---|---|
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -5.0 DC VOLTS NOMINAL 5TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/70.0 DEG CELSIUS |
CWGH | OUTPUT CURRENT RATING | 400.0 DC MILLIAMPERES NOMINAL 5TH POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 2ND POWER OUTPUT |
ABHP | OVERALL LENGTH | 6.500 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APNX | INPUT VOLTAGE RATING | 100.0 AC POUNDS PER HOUR WET 5TH OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS NOMINAL 7TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 5TH OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 5TH OPERATING POWER RQMT |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 7TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 400.0 DC MILLIAMPERES NOMINAL 6TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 800.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 5 4TH POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 5 5TH POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 5TH POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 7TH POWER OUTPUT |
ABKW | OVERALL HEIGHT | 2.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.000 INCHES NOMINAL |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 3RD OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 4TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 220.0 AC POUNDS PER HOUR WET 3RD OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR WET 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 240.0 AC POUNDS PER HOUR WET 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 3RD OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 3RD OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 4TH OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 4TH OPERATING POWER RQMT |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 5 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 5 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 5 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 5 7TH POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 6TH POWER OUTPUT |
ANPM | INPUT PHASE | SINGLE 5TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 117.0 AC POUNDS PER HOUR WET 4TH OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -5.0 DC VOLTS NOMINAL 6TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 800.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 5 6TH POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 4TH POWER OUTPUT |
Relevant Components for NSN - 6130-01-325-6734, 6130013256734 | ||||
6115-00-103-8674 (6115001038674) | 6110-01-641-7160 (6110016417160) | 6145-01-083-0220 (6145010830220) | 6150-01-516-9770 (6150015169770) | |
6150-01-254-9330 (6150012549330) | 6110-00-422-2897 (6110004222897) | 6150-00-922-2200 (6150009222200) | 6150-01-627-9175 (6150016279175) | |
6110-01-108-6732 (6110011086732) | 6130-00-869-0758 (6130008690758) | 6150-01-070-0783 (6150010700783) | 6160-01-467-4040 (6160014674040) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.