If you are looking for NSN 6130-01-027-9013 supplies, turn to Boost AOG and our vast collection of offerings. On this page, we have arranged our NSN 6130-01-027-9013 inventory, where part numbers like 270-0727-040, ET401-1, ET401-11, and others are presented alongside relevant information about this NSN for your perusal. Take the time to browse our ever-expanding selection of components as you see fit, and if any particular items pique your interest, be sure to use our online RFQ service to request quotes for your consideration.
All manufacturers and suppliers whose parts we sell are carefully evaluated by our staff as necessary, and a myriad of products we carry are subjected to diverse levels of testing and inspection for fit, form, and function. Additionally, we are fully committed to addressing the time limitations of our customers who shop on Boost AOG, providing options for accelerated shipping based on availability. Keeping this in mind, do not hesitate to reach out to us directly by phone or email, and our knowledgeable team members would be more than happy to help you obtain the NSN 6130-01-027-9013 parts you desire.
Item Name | Powersupply |
Federal Supply Group (FSG) | Electric Wire and Power and Distribution Equipment |
Federal Supply Class (FSC) | 6130 Converters Electrical Non Rotating |
National Item Identification Number (NIIN) | 01-027-9013 (010279013) |
NCB Code | USA (01) |
Manufacturer | Rockwell Collins Aerospace, Astec America Inc |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 9.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.200 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.900 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM 2ND OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 210.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 250.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS MINIMUM 4TH POWER OUTPUT AND-15.0 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | -5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 15.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 400.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 400.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/70.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 3RD POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 4TH POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 3RD POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 4TH POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
CBBL | FEATURES PROVIDED | EMI FILTER |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 400.0 DC MILLIAMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 6.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 3RD POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 4TH POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 5 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 5 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 5 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 5 4TH POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 4TH POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 1ST OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 2ND OPERATING POWER RQMT |
CWKG | VENTILATION DESIGN TYPE | AMBIENT AIR |
Relevant Components for NSN - 6130-01-027-9013, 6130010279013 | ||||
6145-01-225-2666 (6145012252666) | 6105-00-230-9218 (6105002309218) | 6115-00-284-1957 (6115002841957) | 6130-01-616-3396 (6130016163396) | |
6145-00-635-1537 (6145006351537) | 6130-01-008-6027 (6130010086027) | 6150-01-590-2226 (6150015902226) | 6105-01-183-5489 (6105011835489) | |
6145-01-188-2789 (6145011882789) | 6150-01-280-8673 (6150012808673) | 6130-01-312-4243 (6130013124243) | 6115-01-628-1591 (6115016281591) | |