If you are looking for NSN 5970-00-933-3039 supplies, turn to Boost AOG and our vast collection of offerings. On this page, we have arranged our NSN 5970-00-933-3039 inventory, where part numbers like 562A067-3, 860531-24, 903080-1, and others are presented alongside relevant information about this NSN for your perusal. Take the time to browse our ever-expanding selection of components as you see fit, and if any particular items pique your interest, be sure to use our online RFQ service to request quotes for your consideration.

All manufacturers and suppliers whose parts we sell are carefully evaluated by our staff as necessary, and a myriad of products we carry are subjected to diverse levels of testing and inspection for fit, form, and function. Additionally, we are fully committed to addressing the time limitations of our customers who shop on Boost AOG, providing options for accelerated shipping based on availability. Keeping this in mind, do not hesitate to reach out to us directly by phone or email, and our knowledgeable team members would be more than happy to help you obtain the NSN 5970-00-933-3039 parts you desire.

Item Name Insulation Sleeving Electrical S
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5970 Electrical Insulators and Insulating Materials
National Item Identification Number (NIIN) 00-933-3039 (009333039)
NCB Code USA (00)
Manufacturer Tyco Electronics Corporation, Litton Systems Inc, Northrop Grumman Systems Corporation, General Dynamics Land Systems Inc
Part Number Manufacturer Item Name Cage Code RFQ
562A067-3 tyco electronics corporation insulation sleeving electrical s 06090 RFQ
860531-24 litton systems inc insulation sleeving electrical s 13973 RFQ
860531-24 northrop grumman systems corporation insulation sleeving electrical s 06481 RFQ
903080-1 general dynamics land systems inc insulation sleeving electrical s 05257 RFQ

Technical Characteristics of NSN 5970009333039

MRCCriteriaCharacteristic
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABJHTEMP RATING-55.0 DEG CELSIUS AND 125.0 DEG CELSIUS
ADZCENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
AFZUMAIN BODY INSIDE DIAMETER1.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
AFZUMAIN BODY INSIDE DIAMETER2.190 INCHES MINIMUM AS SUPPLIED
AFZVFIRST BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
AFZVFIRST BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
AFZWSECOND BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
AFZWSECOND BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
AFZXTHIRD BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
AFZXTHIRD BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
AFZYFOURTH BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
AFZYFOURTH BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
AFZZDISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH4.000 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AGAADISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH3.640 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AGABMAIN BODY WALL THICKNESS0.180 INCHES MAXIMUM AS SUPPLIED
AGABMAIN BODY WALL THICKNESS0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AGACFIRST BRANCH WALL THICKNESS0.100 INCHES MAXIMUM AS SUPPLIED
AGACFIRST BRANCH WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AGADSECOND BRANCH WALL THICKNESS0.100 INCHES MAXIMUM AS SUPPLIED
AGADSECOND BRANCH WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AGAETHIRD BRANCH WALL THICKNESS0.100 INCHES MAXIMUM AS SUPPLIED
AGAETHIRD BRANCH WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AGAFFOURTH BRANCH WALL THICKNESS0.100 INCHES MAXIMUM AS SUPPLIED
AGAFFOURTH BRANCH WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AGAGDISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES4.270 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AGAQANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG45.0 NOMINAL AS SUPPLIED
AGARANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG15.0 NOMINAL AS SUPPLIED
CQBCMINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
FLEXFLEXIBILITYSEMIRIGID
HUESCOLORBLACK
MATTMATERIALPLASTIC,POLYOLEFIN,RT-301,RAYCHEM CORP
STYLSTYLE DESIGNATORTRANSITION-1 TO 4 CABLES
UKBGDIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH

Relevant Components for NSN - 5970-00-933-3039, 5970009333039
5998-01-256-1741 (5998012561741) 5935-00-007-7456 (5935000077456) 5910-00-954-9162 (5910009549162) 5950-00-855-7663 (5950008557663)
5935-00-810-8709 (5935008108709) 5960-00-690-9657 (5960006909657) 5975-01-225-3947 (5975012253947) 5998-01-124-5937 (5998011245937)
5995-01-539-9603 (5995015399603) 5925-01-096-4669 (5925010964669) 5920-00-056-6620 (5920000566620) 5905-01-140-2859 (5905011402859)

Recently Viewed Parts

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top