If you are looking for NSN 5950-01-380-9846 supplies, turn to Boost AOG and our vast collection of offerings. On this page, we have arranged our NSN 5950-01-380-9846 inventory, where part numbers like 51-357-01, TF51-357-01, and others are presented alongside relevant information about this NSN for your perusal. Take the time to browse our ever-expanding selection of components as you see fit, and if any particular items pique your interest, be sure to use our online RFQ service to request quotes for your consideration.
All manufacturers and suppliers whose parts we sell are carefully evaluated by our staff as necessary, and a myriad of products we carry are subjected to diverse levels of testing and inspection for fit, form, and function. Additionally, we are fully committed to addressing the time limitations of our customers who shop on Boost AOG, providing options for accelerated shipping based on availability. Keeping this in mind, do not hesitate to reach out to us directly by phone or email, and our knowledgeable team members would be more than happy to help you obtain the NSN 5950-01-380-9846 parts you desire.
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 01-380-9846 (013809846) |
NCB Code | USA (01) |
Manufacturer | Eldec Corporation |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
51-357-01 | eldec corporation | transformer power | 08748 | RFQ |
TF51-357-01 | eldec corporation | transformer power | 08748 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABTB | MOUNTING HOLE DIAMETER | 0.109 INCHES NOMINAL 2ND GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | BRACKET ALL GROUPINGS AND UNTHREADED HOLE ALL GROUPINGS AND SLOT ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 0.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 17.35 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 30.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENT |
ADAT | BODY WIDTH | 2.620 INCHES MAXIMUM |
AKPV | MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
CRBZ | WINDING OPERATING CURRENT | 1.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 0.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 129.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 223.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 5.020 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 5.170 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.218 INCHES MINIMUM 1ST GROUP AND 0.224 INCHES MAXIMUM 1ST GROUP |
AEHZ | MAXIMUM OPERATING TEMP | 200.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.780 INCHES MINIMUM ALL MOUNTING FACILITIES ALL CENTER GROUPINGS AND 1.820 INCHES MAXIMUM ALL MOUNTING FACILITIES ALL CENTER GROUPINGS |
AKPV | MOUNTING FACILITY QUANTITY | 2 2ND GROUP |
CWJS | WINDING OPERATING VOLTAGE | 0.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 5.77 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND FLAME RESISTANT AND SALT SPRAY RESISTANT |
ABTB | MOUNTING HOLE DIAMETER | 0.218 INCHES MINIMUM SINGLE GROUP AND 0.224 INCHES MAXIMUM SINGLE GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.109 INCHES NOMINAL 2ND GROUP |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
CRBZ | WINDING OPERATING CURRENT | 2.27 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 215.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 15 WIRE LEAD |
Relevant Components for NSN - 5950-01-380-9846, 5950013809846 | ||||
5930-00-209-6956 (5930002096956) | 5935-01-191-3975 (5935011913975) | 5985-01-134-5219 (5985011345219) | 5940-01-605-3159 (5940016053159) | |
5985-01-110-2977 (5985011102977) | 5975-01-362-3266 (5975013623266) | 5950-00-711-3339 (5950007113339) | 5910-01-641-9229 (5910016419229) | |
5998-00-234-3618 (5998002343618) | 5998-00-477-0858 (5998004770858) | 5962-01-048-2204 (5962010482204) | 5995-01-256-6986 (5995012566986) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote