INSTANT RFQ

Explore Our NSN 5950-00-944-2861 Inventory

If you are looking for NSN 5950-00-944-2861 supplies, turn to Boost AOG and our vast collection of offerings. On this page, we have arranged our NSN 5950-00-944-2861 inventory, where part numbers like 160801, 927C890-1, 9T33Y6611, T61589, and others are presented alongside relevant information about this NSN for your perusal. Take the time to browse our ever-expanding selection of components as you see fit, and if any particular items pique your interest, be sure to use our online RFQ service to request quotes for your consideration.

All manufacturers and suppliers whose parts we sell are carefully evaluated by our staff as necessary, and a myriad of products we carry are subjected to diverse levels of testing and inspection for fit, form, and function. Additionally, we are fully committed to addressing the time limitations of our customers who shop on Boost AOG, providing options for accelerated shipping based on availability. Keeping this in mind, do not hesitate to reach out to us directly by phone or email, and our knowledgeable team members would be more than happy to help you obtain the NSN 5950-00-944-2861 parts you desire.

Item Name Transformer Power
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5950 Coils and Transformers
National Item Identification Number (NIIN) 00-944-2861 (009442861)
NCB Code USA (00)
Manufacturer Electronic Transformer Corp, General Signal Corp, Bae Systems Controls Inc, General Electric Company, Thordarson Inc
Part Number Manufacturer Item Name Cage Code RFQ
160801 electronic transformer corp transformer power 72149 RFQ
160801 general signal corp transformer power 72419 RFQ
927C890-1 bae systems controls inc transformer power 89954 RFQ
9T33Y6611 general electric company transformer power 03512 RFQ
T61589 thordarson inc transformer power 96256 RFQ

Technical Characteristics of NSN 5950009442861

MRCCriteriaCharacteristic
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.110 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.130 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.110 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.130 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFREQUENCY RATING380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
ACZCINPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT
ACZDTRANSFORMER WINDING CONNECTION TYPEWYE-WYE
ACZFMAXIMUM TRANSFORMER POWER RATING28.1 VOLT-AMPERE SINGLE COMPONENT
ADAQBODY LENGTH3.880 INCHES MAXIMUM
ADATBODY WIDTH2.620 INCHES MAXIMUM
ADAUBODY HEIGHT1.750 INCHES MAXIMUM
AKNAINCLOSURE TYPEFULLY INCLOSED
AKPVMOUNTING FACILITY QUANTITY4 SINGLE GROUP
AXGYMOUNTING METHODTHREADED HOLE SINGLE GROUP
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT
CQJXNOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
CRBZWINDING OPERATING CURRENT17.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
CRBZWINDING OPERATING CURRENT23.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
CRBZWINDING OPERATING CURRENT25.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
CRBZWINDING OPERATING CURRENT600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
CRMJWINDING POWER RATING0.75 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
CRMJWINDING POWER RATING15.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
CRMJWINDING POWER RATING2.25 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
CRMJWINDING POWER RATING2.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
CWJSWINDING OPERATING VOLTAGE25.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY AND 75.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY AND 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
CWJSWINDING OPERATING VOLTAGE26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
CWJSWINDING OPERATING VOLTAGE30.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE36.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 144.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
FEATSPECIAL FEATURESONE PRIMARY WINDING; SIX SECONDARY WINDINGS WITH 3RD AND 6TH WINDINGS CENTER TAPPED AND 1ST AND 4TH WINDINGS MULTIPLE TAPPED W/CENTER TAP
THSDTHREAD SERIES DESIGNATORUNC SINGLE GROUP
TTQYTERMINAL TYPE AND QUANTITY24 TURRET

Relevant Components for NSN - 5950-00-944-2861, 5950009442861
5935-01-264-3240 (5935012643240) 5910-01-115-9700 (5910011159700) 5962-00-001-1902 (5962000011902) 5930-00-009-7511 (5930000097511)
5962-01-426-0084 (5962014260084) 5935-00-900-9127 (5935009009127) 5998-00-069-5683 (5998000695683) 5930-00-472-3228 (5930004723228)
5945-00-701-1784 (5945007011784) 5905-00-009-6425 (5905000096425) 5961-01-381-7607 (5961013817607) 5995-01-394-0372 (5995013940372)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.