If you are looking for NSN 5950-00-279-4018 supplies, turn to Boost AOG and our vast collection of offerings. On this page, we have arranged our NSN 5950-00-279-4018 inventory, where part numbers like 25P237501-21-11, TT1-10835, and others are presented alongside relevant information about this NSN for your perusal. Take the time to browse our ever-expanding selection of components as you see fit, and if any particular items pique your interest, be sure to use our online RFQ service to request quotes for your consideration.
All manufacturers and suppliers whose parts we sell are carefully evaluated by our staff as necessary, and a myriad of products we carry are subjected to diverse levels of testing and inspection for fit, form, and function. Additionally, we are fully committed to addressing the time limitations of our customers who shop on Boost AOG, providing options for accelerated shipping based on availability. Keeping this in mind, do not hesitate to reach out to us directly by phone or email, and our knowledgeable team members would be more than happy to help you obtain the NSN 5950-00-279-4018 parts you desire.
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 00-279-4018 (002794018) |
NCB Code | USA (00) |
Manufacturer | Herley Chicago, Transformer Technicians Inc |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
25P237501-21-11 | herley chicago | transformer power | 98738 | RFQ |
TT1-10835 | transformer technicians inc | transformer power | 96253 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.940 INCHES MAXIMUM3.940 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.970 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.970 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.030 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.030 INCHES MAXIMUM SINGLE MOUNTIN |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.350 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.350 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.410 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.410 INCHES MAXIMUM SINGLE MOUNTIN |
ABMK | OVERALL WIDTH | 2.120 INCHES MAXIMUM2.120 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.940 INCHES MAXIMUM3.940 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 9 SECONDARY SINGLE COMPONENT9 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 150.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 185.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 300.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 236.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY130.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY236.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 236.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY552.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 236.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY130.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 552.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 552.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY236.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY236.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING; 9 SECONDARY WINDINGS |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 27 STANDOFF,SOLDER LUG |
Relevant Components for NSN - 5950-00-279-4018, 5950002794018 | ||||
5935-01-653-6676 (5935016536676) | 5995-01-105-7504 (5995011057504) | 5975-01-415-2357 (5975014152357) | 5999-01-075-4387 (5999010754387) | |
5955-01-642-3824 (5955016423824) | 5995-01-282-6623 (5995012826623) | 5999-00-678-2672 (5999006782672) | 5962-01-262-0186 (5962012620186) | |
5935-01-208-6343 (5935012086343) | 5999-01-095-3494 (5999010953494) | 5961-01-094-8785 (5961010948785) | 5935-00-280-2838 (5935002802838) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.