If you are looking for NSN 5950-00-273-3960 supplies, turn to Boost AOG and our vast collection of offerings. On this page, we have arranged our NSN 5950-00-273-3960 inventory, where part numbers like 005419, 701915, and others are presented alongside relevant information about this NSN for your perusal. Take the time to browse our ever-expanding selection of components as you see fit, and if any particular items pique your interest, be sure to use our online RFQ service to request quotes for your consideration.
All manufacturers and suppliers whose parts we sell are carefully evaluated by our staff as necessary, and a myriad of products we carry are subjected to diverse levels of testing and inspection for fit, form, and function. Additionally, we are fully committed to addressing the time limitations of our customers who shop on Boost AOG, providing options for accelerated shipping based on availability. Keeping this in mind, do not hesitate to reach out to us directly by phone or email, and our knowledgeable team members would be more than happy to help you obtain the NSN 5950-00-273-3960 parts you desire.
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 00-273-3960 (002733960) |
NCB Code | USA (00) |
Manufacturer | Magnetika Inc, United Transformer Corp, Ge Aviation Systems Ltd, Electronic Transformer Corp |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 4.875 INCHES MAXIMUM4.875 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 6.500 INCHES MAXIMUM6.500 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.125 INCHES MAXIMUM3.125 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL SINGLE GROUP0.188 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SIX PHASE SINGLE COMPONENT AND THREE PHASE TO SIX PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 11 SECONDARY SINGLE COMPONENT11 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 7.0 AMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 12.9 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY283.7 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 268.8 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY76.8 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 283.7 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 76.8 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY12.9 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 142.00 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 31.20 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 149.00 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY32.80 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.20 AC VOLTS MINIMUM AND 22.20 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.20 AC VOLTS MINIMUM SINGLE COMPONENT 4TH SECONDARY AND 176.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 192.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 22.20 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY200.00 AC |
CWJS | WINDING OPERATING VOLTAGE | 21.20 AC VOLTS MINIMUM SINGLE COMPONENT 4TH SECONDARY AND 21.20 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 22.20 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY22.20 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 31.20 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 32.80 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY AND ELEVEN SECONDARIES |
TTQY | TERMINAL TYPE AND QUANTITY | 16 TAB,SOLDER LUG AND 49 TURRET |
Relevant Components for NSN - 5950-00-273-3960, 5950002733960 | ||||
5935-01-264-3240 (5935012643240) | 5910-01-115-9700 (5910011159700) | 5962-00-001-1902 (5962000011902) | 5930-00-009-7511 (5930000097511) | |
5962-01-426-0084 (5962014260084) | 5935-00-900-9127 (5935009009127) | 5998-00-069-5683 (5998000695683) | 5930-00-472-3228 (5930004723228) | |
5945-00-701-1784 (5945007011784) | 5905-00-009-6425 (5905000096425) | 5961-01-381-7607 (5961013817607) | 5995-01-394-0372 (5995013940372) | |