MRC | Criteria | Characteristic |
---|
AAJD | THREAD CLASS | 2A |
AAJF | THREAD DIRECTION | RIGHT-HAND |
AAQL | BODY STYLE | STRAIGHT SHAPE,EXTERNAL COUPLING W/BACKSHELL |
ABHP | OVERALL LENGTH | 1.662 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 1.344 INCHES MINIMUM AND 1.406 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.344 INCHES MINIMUM AND 1.406 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT AND VIBRATION RESISTANT AND SALT WATER RESISTANT |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.115 INCHES MINIMUM AND 0.130 INCHES MAXIMUM |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 1.046 INCHES MINIMUM AND 1.078 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.046 INCHES MINIMUM AND 1.078 INCHES MAXIMUM |
AFQK | DISTANCE FROM MOUNTING SHOULDER TO FRONT FACE | 0.750 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
AFQR | THREADED DEVICE TYPE | COUPLING FACILITY |
AFQW | MATING END QUANTITY | 1 |
AFQX | CONTACT POSITION ARRANGEMENT STYLE | 18-1 SINGLE MATING END |
AFQZ | CONTACT REMOVABILITY | REMOVABLE SINGLE MATING END ALL CONTACT GROUPINGS |
AFRC | CONTACT MAXIMUM CURRENT RATING IN AMPS | 22.0 SINGLE MATING END ALL CONTACT GROUPINGS |
AFRD | CONTACT MAXIMUM AC VOLTAGE RATING IN VOLTS | 200.0 SINGLE MATING END 2ND CONTACT GROUPING |
AFRD | CONTACT MAXIMUM AC VOLTAGE RATING IN VOLTS | 500.0 SINGLE MATING END 1ST CONTACT GROUPING |
AFRE | CONTACT MAXIMUM DC VOLTAGE RATING IN VOLTS | 250.0 SINGLE MATING END 2ND CONTACT GROUPING |
AFRE | CONTACT MAXIMUM DC VOLTAGE RATING IN VOLTS | 700.0 SINGLE MATING END 1ST CONTACT GROUPING |
AFRN | POLARIZATION METHOD | KEYWAY OR MULTIPLE KEYWAY |
AFRP | INSERT POSITION IN DEG | 70.0 |
AFRT | SHELL TYPE | SOLID |
AFRV | CONNECTOR LOCKING METHOD | EXTERNALLY THREADED SHELL |
AKMG | NOMINAL THREAD LENGTH | 0.625 INCHES |
CQJX | NOMINAL THREAD SIZE | 1.125 INCHES |
CQTM | TERMINAL LOCATION | BACK SINGLE MATING END ALL CONTACT GROUPINGS |
CSCF | TERMINAL TYPE | CRIMP SINGLE MATING END ALL CONTACT GROUPINGS |
CSPT | SHELL MATERIAL | ALUMINUM ALLOY |
CSWM | SHELL SURFACE TREATMENT | CADMIUM |
CTBC | SHELL SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | QQ-P-416,TY 2,CL 3 FED SPEC SINGLE TREATMENT RESPONSE |
CXCG | INCLUDED CONTACT QUANTITY | 4 SINGLE MATING END 1ST CONTACT GROUPING |
CXCG | INCLUDED CONTACT QUANTITY | 6 SINGLE MATING END 2ND CONTACT GROUPING |
CXCL | INCLUDED CONTACT TYPE | ROUND SOCKET SINGLE MATING END ALL CONTACT GROUPINGS |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-5015 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
THSD | THREAD SERIES DESIGNATOR | UNEF |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-5015 GOVERNMENT SPECIFICATION |