If you are looking for NSN 5925-01-485-9638 supplies, turn to Boost AOG and our vast collection of offerings. On this page, we have arranged our NSN 5925-01-485-9638 inventory, where part numbers like 10047, 927439-0013, M39019/03-055S, M39019/03-248S, MIL-PRF-39019/3, and others are presented alongside relevant information about this NSN for your perusal. Take the time to browse our ever-expanding selection of components as you see fit, and if any particular items pique your interest, be sure to use our online RFQ service to request quotes for your consideration.
All manufacturers and suppliers whose parts we sell are carefully evaluated by our staff as necessary, and a myriad of products we carry are subjected to diverse levels of testing and inspection for fit, form, and function. Additionally, we are fully committed to addressing the time limitations of our customers who shop on Boost AOG, providing options for accelerated shipping based on availability. Keeping this in mind, do not hesitate to reach out to us directly by phone or email, and our knowledgeable team members would be more than happy to help you obtain the NSN 5925-01-485-9638 parts you desire.
Item Name | Circuit Breaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 01-485-9638 (014859638) |
NCB Code | USA (01) |
Manufacturer | Ap Labs Inc, Northrop Grumman Systems Corporation, Military Specifications |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
10047 | ap labs inc | circuit breaker | 1z496 | RFQ |
927439-0013 | northrop grumman systems corporation | circuit breaker | 06481 | RFQ |
M39019/03-055S | military specifications | circuit breaker | 81349 | RFQ |
M39019/03-248S | military specifications | circuit breaker | 81349 | RFQ |
MIL-PRF-39019/3 | military specifications | circuit breaker | 81349 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC ALL LOCATIONS AND 10.0 AMPERES DC ALL LOCATIONS |
ABXD | Bushing Length | 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
AJWX | Mounting Surface To Terminal End Distance | 1.828 INCHES MAXIMUM |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 300.0 AC ALL LOCATIONS AND 500.0 DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
ADAT | Body Width | 1.281 INCHES MAXIMUM |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | METAL |
CPRW | Actuator Function | TRIP-RESET |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
THSD | Thread Series Designator | UNEF |
CQJX | Nominal Thread Size | 0.375 INCHES |
AAQL | Body Style | |
ADAQ | Body Length | 1.562 INCHES MAXIMUM |
BBRJ | Special Handling Feature | MAGNETIC |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.906 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CMLP | Thread Quantity Per Inch | 32 |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM |
CPRH | Circuit Protection Type | REVERSE PHASE ALL LOCATIONS |
ZZZK | Specification/Standard Data | 81349-MIL-PRF-39019/3 GOVERNMENT SPECIFICATION |
AFJN | Fragility Factor | MODERATELY RUGGED |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.055 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.950 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
TTQY | Terminal Type And Quantity | 4 SCREW |
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF AND FUNGUS PROOF AND HERMETICALLY SEALED AND MOISTURE PROOF |
MRC | Decoded Requirement | Clear Text Reply |
TEST | Test Data Document | 81349-MIL-PRF-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
Relevant Components for NSN - 5925-01-485-9638, 5925014859638 | ||||
5905-01-333-0379 (5905013330379) | 5905-01-073-6984 (5905010736984) | 5905-01-101-7732 (5905011017732) | 5998-01-283-3416 (5998012833416) | |
5935-01-225-8978 (5935012258978) | 5930-01-276-8776 (5930012768776) | 5935-01-302-0287 (5935013020287) | 5940-00-144-1527 (5940001441527) | |
5970-00-211-5738 (5970002115738) | 5975-01-458-4880 (5975014584880) | 5970-00-194-3070 (5970001943070) | 5996-01-370-7251 (5996013707251) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote