Item Name | Circuitbreaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 00-782-0113 (007820113) |
NCB Code | USA (00) |
Manufacturer | Northrop Grumman Systems Corporation, Westinghouse Electric Corp, Eaton Corporation, Dla Land And Maritime |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
335C757H61 | northrop grumman systems corporation | circuitbreaker | 97942 | RFQ |
335C757H61 | westinghouse electric corp | circuitbreaker | 79500 | RFQ |
AM17 | eaton corporation | circuitbreaker | 74193 | RFQ |
AM17-2.0A | eaton corporation | circuitbreaker | 74193 | RFQ |
DMS83059B | dla land and maritime | circuitbreaker | 16236 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ADAQ | BODY LENGTH | 2.500 INCHES NOMINAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 2.0 AMPERES AC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 60.000 NOMINAL SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | EXPLOSION RESISTANT AND HERMETICALLY SEALED |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAT | BODY WIDTH | 0.750 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.190 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.812 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.000 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 30.000 NOMINAL AT 150 PCT AND 12.000 NOMINAL AT 200 PCT AND 3.000 NOMINAL AT 300 PCT AND 1.500 NOMINAL AT 400 PCT SINGLE LOCATION |
TEST | TEST DATA DOCUMENT | 97942-335C757 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
Relevant Components for NSN - 5925-00-782-0113, 5925007820113 | ||||
5905-00-284-5850 (5905002845850) | 5910-00-615-5501 (5910006155501) | 5985-01-673-8882 (5985016738882) | 5940-01-605-8237 (5940016058237) | |
5998-00-050-1782 (5998000501782) | 5905-01-410-2888 (5905014102888) | 5905-01-285-8665 (5905012858665) | 5950-01-020-0609 (5950010200609) | |
5930-01-455-8048 (5930014558048) | 5935-01-313-4424 (5935013134424) | 5905-00-284-3888 (5905002843888) | 5995-01-713-4352 (5995017134352) | |