If you are looking for NSN 5925-00-403-4061 supplies, turn to Boost AOG and our vast collection of offerings. On this page, we have arranged our NSN 5925-00-403-4061 inventory, where part numbers like AM333HEMG6-15-250-400-14, and others are presented alongside relevant information about this NSN for your perusal. Take the time to browse our ever-expanding selection of components as you see fit, and if any particular items pique your interest, be sure to use our online RFQ service to request quotes for your consideration.
All manufacturers and suppliers whose parts we sell are carefully evaluated by our staff as necessary, and a myriad of products we carry are subjected to diverse levels of testing and inspection for fit, form, and function. Additionally, we are fully committed to addressing the time limitations of our customers who shop on Boost AOG, providing options for accelerated shipping based on availability. Keeping this in mind, do not hesitate to reach out to us directly by phone or email, and our knowledgeable team members would be more than happy to help you obtain the NSN 5925-00-403-4061 parts you desire.
Item Name | Circuit Breaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 00-403-4061 (004034061) |
NCB Code | USA (00) |
Manufacturer | Eaton Corporation |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
AM333HEMG6-15-250-400-14 | eaton corporation | circuit breaker | 74193 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND |
CQXF | Inclosure Protection Type For Which Designed | SALT SPRAY PROOF |
MRC | Decoded Requirement | Clear Text Reply |
BBRJ | Special Handling Feature | MAGNETIC |
CPLM | Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | MOISTURE RESISTANT AND |
AFJN | Fragility Factor | MODERATELY RUGGED |
THSD | Thread Series Designator | UNC |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
TEST | Test Data Document | 13499-260-4015 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AKPX | Pole Quantity | 3 |
CSSX | Switch Current Rating And Type In Amps | 1.0 DC |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 115.0 ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CSSX | Switch Current Rating And Type In Amps | 2.5 AC AND |
AJEC | Boss Height | 0.140 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.250 INCHES NOMINAL |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT EACH POLE |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
AAJE | Thread Pitch Diameters | 0.1177 TO 0.1214 INCHES |
CSWP | Switch Voltage Rating And Type In Volts | 50.0 DC |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.611 INCHES NOMINAL |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
CMLP | Thread Quantity Per Inch | 32 |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.938 INCHES NOMINAL |
PKWT | Unpackaged Unit Weight | 14.250 OUNCES |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 20.000 MINIMUM AT 200 PCT AND |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | SHOCK RESISTANT AND |
CQXF | Inclosure Protection Type For Which Designed | HUMIDITY RESISTANT AND |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |
Relevant Components for NSN - 5925-00-403-4061, 5925004034061 | ||||
5935-99-258-1998 (5935992581998) | 5963-01-520-9969 (5963015209969) | 5905-01-092-1557 (5905010921557) | 5998-01-371-0485 (5998013710485) | |
5985-01-607-6492 (5985016076492) | 5961-01-318-3091 (5961013183091) | 5910-01-651-4692 (5910016514692) | 5995-01-413-7080 (5995014137080) | |
5998-00-491-7782 (5998004917782) | 5962-01-111-0887 (5962011110887) | 5935-00-013-9074 (5935000139074) | 5950-01-158-7851 (5950011587851) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.