INSTANT RFQ

NSN 5915001168306 Filter Radio Freque Parts Directory

Item Name Filter Radio Freque
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5915 Filters and Networks
National Item Identification Number (NIIN) 00-116-8306 (001168306)
NCB Code USA (00)
Manufacturer Bae Systems Inc
Part Number Manufacturer Item Name Cage Code RFQ
292072P1 bae systems inc filter radio freque 94117 RFQ
EM1F0043 bae systems inc filter radio freque 94117 RFQ

Technical Characteristics of NSN 5915001168306

MRCCriteriaCharacteristic
ABKWOVERALL HEIGHT2.840 INCHES MAXIMUM
ADAQBODY LENGTH1.937 INCHES NOMINAL
ADATBODY WIDTH1.468 INCHES NOMINAL
ADAUBODY HEIGHT2.000 INCHES NOMINAL
AFGAOPERATING TEMP RANGE-55.0 TO 71.0 DEG CELSIUS
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.2 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.2 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.2 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
AHCGMAXIMUM TEMP RISE25.0 DEG CELSIUS
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AXHRMOUNTING FACILITY TYPE AND QUANTITY1 THREADED STUD
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY2 TURRET GROUND 3RD FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY3 TURRET INPUT 1ST FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY3 TURRET OUTPUT 2ND FUNCTION
CQDZMAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE230.0 VOLTS AT SEA LEVEL
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQRGBODY MATERIALMETAL
CRSTBODY SURFACE TREATMENTTIN
CTJSUNPACKAGED UNIT WEIGHT8.000 OUNCES NOMINAL
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE

Relevant Components for NSN - 5915-00-116-8306, 5915001168306
5995-01-325-3046 (5995013253046) 5950-00-648-5897 (5950006485897) 5930-01-421-4933 (5930014214933) 5930-01-205-2006 (5930012052006)
5985-01-594-0315 (5985015940315) 5980-01-248-8503 (5980012488503) 5999-01-433-6693 (5999014336693) 5998-01-549-2369 (5998015492369)
5960-00-583-4843 (5960005834843) 5995-01-258-5654 (5995012585654) 5935-01-378-4937 (5935013784937) 5905-01-120-8571 (5905011208571)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top